Difficulty: Medium
Average Score: 87%
Simulated
A nurse is preparing to measure a client's level of oxygen saturation and observes edema of both hands and thickened toenails. The nurse should apply the pulse oximeter probe to which of the following locations?
Correct answer
D
Rationale
The correct answer is D: Earlobe. The nurse should apply the pulse oximeter probe to the earlobe because in this scenario, the client has edema of both hands and thickened toenails, which can affect the accuracy of readings on the fingers or toes. The earlobe is a reliable alternative site for obtaining accurate oxygen saturation readings in patients with peripheral edema or thickened nails. It provides good blood flow and is less affected by local edema or nail thickness compared to the fingers or toes. Skin folds can also be affected by edema, making them less reliable. Therefore, the earlobe is the best choice in this situation for accurate oxygen saturation measurement.