Difficulty: Medium
Average Score: 75%
Testbank
A patient has just returned to the floor following a transurethral resection of the prostate. A triple-lumen indwelling urinary catheter has been inserted for continuous bladder irrigation. What, in addition to balloon inflation, are the functions of the three lumens?
Correct answer
A
Rationale
Continuous inflow and outflow of irrigation solution are essential functions of the three lumens in a triple-lumen catheter following a transurethral resection of the prostate.
This option is correct because the triple-lumen catheter allows for continuous irrigation of the bladder while simultaneously providing a pathway for urine to drain out. This helps maintain bladder patency and prevents clot formation, which is crucial after such a surgical procedure.
B: Intermittent inflow and continuous outflow of irrigation solution fails because continuous irrigation is necessary to prevent clot formation and ensure effective bladder irrigation after the procedure.
C: Continuous inflow and intermittent outflow of irrigation solution does not align with the need for consistent drainage of urine and irrigation solution, which is vital for maintaining bladder function post-surgery.
D: Intermittent flow of irrigation solution and prevention of hemorrhage is inaccurate, as the triple-lumen catheter is designed for continuous irrigation rather than intermittent flow, and hemorrhage prevention is primarily managed through other means, not the catheter's irrigation function.
This option is correct because the triple-lumen catheter allows for continuous irrigation of the bladder while simultaneously providing a pathway for urine to drain out. This helps maintain bladder patency and prevents clot formation, which is crucial after such a surgical procedure.
B: Intermittent inflow and continuous outflow of irrigation solution fails because continuous irrigation is necessary to prevent clot formation and ensure effective bladder irrigation after the procedure.
C: Continuous inflow and intermittent outflow of irrigation solution does not align with the need for consistent drainage of urine and irrigation solution, which is vital for maintaining bladder function post-surgery.
D: Intermittent flow of irrigation solution and prevention of hemorrhage is inaccurate, as the triple-lumen catheter is designed for continuous irrigation rather than intermittent flow, and hemorrhage prevention is primarily managed through other means, not the catheter's irrigation function.