Difficulty: Medium
Average Score: 84%
Testbank
The nurse is caring for a patient who is in the recovery room following the implantation of an ICD. The patient has developed ventricular tachycardia (VT). What should the nurse assess and document?
Correct answer
A
Rationale
A: ECG to compare time of onset of VT and onset of devices shock.
Assessing the ECG to compare the time of onset of ventricular tachycardia (VT) with the onset of device shock is crucial in determining the effectiveness of the ICD and understanding the patient's response to the dysrhythmia. This information is essential for guiding further interventions and evaluating the device's performance during an acute event.
B: ECG so physician can see what type of dysrhythmia the patient has. While identifying the type of dysrhythmia is important, the immediate priority in this context is to assess the relationship between the onset of VT and the ICD shock to evaluate device functionality.
C: Patients level of consciousness (LOC) at the time of the dysrhythmia. Although assessing LOC is important in a broader context, it does not provide the specific data needed to evaluate the timing and effectiveness of the ICD intervention during the VT episode.
D: Patients activity at time of dysrhythmia. Knowing the patient's activity at the time of the dysrhythmia may provide context, but it does not directly address the critical assessment needed to correlate the VT onset with the device's response.
Assessing the ECG to compare the time of onset of ventricular tachycardia (VT) with the onset of device shock is crucial in determining the effectiveness of the ICD and understanding the patient's response to the dysrhythmia. This information is essential for guiding further interventions and evaluating the device's performance during an acute event.
B: ECG so physician can see what type of dysrhythmia the patient has. While identifying the type of dysrhythmia is important, the immediate priority in this context is to assess the relationship between the onset of VT and the ICD shock to evaluate device functionality.
C: Patients level of consciousness (LOC) at the time of the dysrhythmia. Although assessing LOC is important in a broader context, it does not provide the specific data needed to evaluate the timing and effectiveness of the ICD intervention during the VT episode.
D: Patients activity at time of dysrhythmia. Knowing the patient's activity at the time of the dysrhythmia may provide context, but it does not directly address the critical assessment needed to correlate the VT onset with the device's response.