Difficulty: Medium
Average Score: 85%
Testbank
The nurse is caring for a patient admitted with an acute exacerbation of chronic obstructive pulmonary disease. During assessment, the nurse finds that the patient is experiencing increased dyspnea. What is the most accurate measurement of the concentration of oxygen in the patients blood?
Correct answer
C
Rationale
C: An arterial blood gas (ABG) study provides the most accurate measurement of the concentration of oxygen in a patient's blood, especially in cases of acute exacerbations of chronic obstructive pulmonary disease (COPD).
An ABG study directly measures the partial pressures of oxygen and carbon dioxide in arterial blood, providing precise information about the patient's respiratory status and gas exchange, which is crucial for managing increased dyspnea in COPD patients.
A: A capillary blood sample does not provide as accurate a representation of arterial oxygen levels as an ABG study, making it less suitable for assessing oxygen concentration in this acute situation.
B: Pulse oximetry measures peripheral oxygen saturation but may not accurately reflect true arterial oxygen levels, especially in patients with respiratory distress, making it less reliable for this assessment.
D: A complete blood count (CBC) evaluates overall blood components but does not measure oxygen concentration directly, thus failing to provide the necessary information for managing the patient's dyspnea in COPD.
An ABG study directly measures the partial pressures of oxygen and carbon dioxide in arterial blood, providing precise information about the patient's respiratory status and gas exchange, which is crucial for managing increased dyspnea in COPD patients.
A: A capillary blood sample does not provide as accurate a representation of arterial oxygen levels as an ABG study, making it less suitable for assessing oxygen concentration in this acute situation.
B: Pulse oximetry measures peripheral oxygen saturation but may not accurately reflect true arterial oxygen levels, especially in patients with respiratory distress, making it less reliable for this assessment.
D: A complete blood count (CBC) evaluates overall blood components but does not measure oxygen concentration directly, thus failing to provide the necessary information for managing the patient's dyspnea in COPD.